Generator Error Codes
  • 25 May 2022
  • 5 Minutes to read
  • Contributors
  • Dark
    Light
  • PDF

Generator Error Codes

  • Dark
    Light
  • PDF

Analogue Control Panel Error Codes

Can be found on this article: Analogue Error Codes

X-Control Panel Error Codes

The diagram above explains how to find the error code on a generator digital control panel.


Refer to the table below to understand the description, cause, and action relating to a generator error code.

No.


Description

Cause

Fischer Panda Explanation

Warning

Gen.Stop

HQ Rep

Location Rep

Notes

1

AC Voltage

Voltage too low

yes

yes

Service Support

Electrician

Stop Shift, Organise Electrician, Pass to VOPS Elec, VCS Documentation

2

AC Frequency

Frequency too low

yes

yes

Service Support

Electrician

Stop Shift, Organise Electrician, Pass to VOPS Elec, VCS Documentation

5

Emergency

Emergency button pushed

"Emergency" contact open

n.a.

yes

7

Oil pressure

Oil pressure too low

Failure oil pressure switch

n.a.

yes

Service Support

Diesel Mechanic

Stop Shift, Try VL first then Diesel Mechanic, Changing Oil/Check Oil

13

Starter power

Starter failure

Short circuit starter defect

yes

n.a.

VOPS Elec

Vehicle Leader

14

Glow circuit

Glow circuit failure

Short circuit defect

yes

n.a.

Service Support

Diesel Mechanic

Organise Diesel Mechanic, Replacing/Checking Glow Plugs Documentation

16

Fuel supply

Failure fuel supply

Short circuit defect

yes

n.a.

Service Support

Diesel Mechanic

Refer to GENERATOR FUEL SUPPLY FAILURE

17

Stop solenoid - Hold

Failure stop solenoid hold coil

Short circuit

yes

n.a.

Service Support

Diesel Mechanic

Organise Diesel Mechanic, Stop Solenoid Documentation

18

Stop solenoid - Pull

Failure stop solenoid pull coil

Short circuit

yes

n.a.

Service Support

Diesel Mechanic

Organise Diesel Mechanic, Stop Solenoid Documentation

19

Optional DC out

Failure optional DC out

Short circuit

yes

n.a.

Service Support

General Volunteer

Talk to Vol, Optional DC Out Documentation else pass to VOPS

20

Current sensor

No voltage on supply current sensor

Short circuit defect

yes

VOPS Mech

Diesel Mechanic

25

Battery voltage

Battery voltage too low

yes

yes

Service Support

General Volunteer

Battery Low, Refer Start Battery Documentation with Vol, else VL, else VOPS

26

RPM failure

RPM out of range

Failure fuel supply Fuel empty

n.a.

yes

VOPS

Diesel Mechanic

29

Power out relay

Failure power out relay

Short circuit

n.a.

n.a.

VOPS

Diesel Mechanic

30

AC Voltage L2

Voltage too low L2

yes

yes

VOPS Elec

Electrician

31

AC Frequency L2

Frequency too low L2

yes

yes

VOPS Elec

Electrician

34

AC Voltage L3

Voltage too low L3

yes

yes

VOPS Elec

Electrician

35

AC Frequency L3

Frequency too low L3

yes

yes

VOPS Elec

Electrician

63

Fuel level

Fuel Level too low

yes

no

VOPS Mech

Diesel Mechanic

Refill Van

65

AC Voltage

Voltage too high

yes

yes

Service Support

Electrician

Stop Shift, Organise Electrician, Pass to VOPS Elec, VCS Documentation

66

AC Frequency

Frequency too high

yes

yes

Service Support

Electrician

Stop Shift, Organise Electrician, Pass to VOPS Elec, VCS Documentation

67

AC Current

Current too high

yes

n.a.

Service Support

Electrician

Stop Shift, Organise Electrician, Pass to VOPS Elec, VCS Documentation

68

AC Power

Load too high

yes

n.a.

Service Support

Electrician

Stop Shift, Organise Electrician, Pass to VOPS Elec, VCS Documentation

70

Servo Power

Power too high

Mechanically blocked. Power consumption too high, short circuit

yes

yes

Service Support

Electrician

Stop Shift, Organise Electrician, 240V Documentation

72

Temperature Cylinder head

Temp. value too high

yes

yes

VOPS Mech

Diesel Mechanic

Refer to GENERATOR OVERHEATING FAILURE

73

Temperature Winding

Temp. value too high

yes

yes

VOPS Mech

Diesel Mechanic

Refer to GENERATOR OVERHEATING FAILURE

74

Temperature Exhaust

Temp. value too high

yes

yes

VOPS Mech

Diesel Mechanic

Refer to GENERATOR OVERHEATING FAILURE

75

Temperature Electronics

Temp. value too high

yes

n.a.

VOPS Mech

Diesel Mechanic

77

Starter power

Starter failure

Short circuit starter defect

yes

n.a.

VOPS Elec

Diesel Mechanic

78

Glow circuit

Glow circuit failure

Short circuit defect

yes

n.a.

VOPS Mech

Diesel Mechanic

Organise Diesel Mechanic, Replacing/Checking Glow Plugs Documentation

80

Fuel Supply

Failure fuel supply

Short circuit defect

yes

n.a.

VOPS Mech

Diesel Mechanic

Refer to GENERATOR FUEL SUPPLY FAILURE

81

Stop Solenoid - Hold

Failure stop solenoid hold coil

Short circuit

yes

n.a.

VOPS Mech

Diesel Mechanic

82

Stop Solenoid - Pull

Failure stop solenoid pull coil

Short circuit

yes

n.a.

VOPS Mech

Diesel Mechanic

83

Optional DC Out

Failure oprtional DC out

Short circuit

yes

n.a.

VOPS Elec

General Volunteer

84

Power Supply

Current sensor current too high

Short circuit defect

yes

yes

VOPS Mech

Diesel Mechanic

85

Boost Relay

Failure boost relay

Short circuit or too many modules

yes

yes

Service Support

Electrician

Stop Shift, Organise Electrician, Pass to VOPS Elec, VCS Documentation

86

Bus Power

Bus power consumption high

Short circuit

yes

no

VOPS Elec

Electrician

89

Battery Voltage

Battery voltage too high

yes

yes

VOPS Elec

Electrician

Not relevant. Started battery is 12-24V so not applicable to our system.

93

Power Out Relay

Failure power out relay

Short circuit or defect

yes

yes

VOPS Mech

Electrician

94

AC Voltage L2

Voltage too high L2

yes

yes

95

AC Frequency L2

Frequency too high L2

yes

yes

96

AC Current L2

Current too high L2

yes

n.a.

97

AC Power L2

Power too high L2

yes

n.a.

98

AC Voltage L3

Voltage too high L3

yes

yes

99

AC Frequency L3

Frequency too high L3

yes

yes

100

AC Current L3

Current too high L3

yes

n.a.

101

AC Power L3

Power too high L3

yes

n.a.

126

Temperature Fuel

Fuel temperature too high

yes

n.a.

VOPS Mech

Diesel Mechanic

130

No Panel Found

Wrong patch cable/ wrong contact

Check cable/ harness

n.a.

yes

VOPS

Vehicle Leader

131

Communication FP BUS

Communication failure

Lost communication with panel

n.a.

yes

VOPS

Vehicle Leader

132

Service Interval

Service due

yes

n.a.

Service Support

Vehicle Leader

Walk through Servical Interval Doc with Vol or VL

133

BUS Module Lost (3ph - measurement)

yes

n.a.

VOPS

Vehicle Leader

134

BUS Module Lost (DC - measurement)

n.a.

yes

VOPS

Vehicle Leader

135

Sync Failure

Generators cannot be synced

yes

136

Communication Motor Controller

No data from sync module

Short circuit defect

yes

137

Air Filter

Error air filter

Bad air filter

yes

VOPS Mech

Diesel Mechanic

Inspect generator air filter

139

Sync Module

No data from sync module

Short circuit defect

yes

VOPS

Vehicle Leader

140

Load Balancing

Generator takes less load

Generator produces insufficient power

yes

VOPS

Vehicle Leader

141

Configuration Sync Module

Sync module available but not selected

Crippled mode only

no

VOPS

Vehicle Leader

246

Service Done

user

Service interval reset

n.a.

n.a.

Service Support

Vehicle Leader

Restart Display

251

Admin Param Changed

user

Parameter changed at admin level

n.a.

n.a.

VOPS

Vehicle Leader

255

Reserved

n.a.